A heart rate sensor and a blood lactate prediction can both appear in an exercise study, but their errors come from different steps. One number comes from comparing two readings taken during the same ride. The other comes from a model learning how several signals tend to change with lactate. In this experiment, the difference shows up as soon as you look past the correlation.

THE SHORT READ
  • The heart rate comparison to a chest strap had a mean absolute error of 0.89 beats per minute across 35 people.
  • Only 23 of 36 volunteers had complete temperature profiles. The temperature comparator was another ear measurement.
  • The best lactate model had a correlation of 0.838 and a mean absolute error of 1.528 mmol/L. Agreement limits ran from −4.52 to +4.55 mmol/L.
THE STUDY AT A GLANCEEarbud tracking during incremental cycling · Camargo et al.
Paper date
20 November 2026
Volunteer sample
36 healthy adults
Exercise setting
Controlled incremental cycling
Lactate model evaluation
Leave one participant out at a time

Original publication: 20 Nov 2026 · The date above refers to this brief.

THE NUMBERS, IN CONTEXT

Lactate prediction error across tested inputs

mmol/L MAE

Heart rate only3.538
Temperature only1.642
Two basic features1.67
Full five-feature model1.528
04
Smallest reported mean absolute error for each feature set. The winning algorithms differ across rows. Errors were estimated by holding out one participant at a time.
THE EXPERIMENT, EXPLAINED

Three ways to judge a model result

  1. Direction

    Correlation says how closely predictions and measurements move together.

  2. Size

    Mean absolute error gives the average size of the error in the measurement’s own units.

  3. Spread

    Limits of agreement show how widely individual differences can vary in this dataset.

Press-News guide to reading the model statistics.

Each comparison used a different reference

Volunteers rode a stationary cycle at increasing workloads. A Polar H10 chest strap supplied the comparison heart rate. The earbud differed from it by 0.89 beats per minute on average when differences were counted without their signs. The study reports 7,568 paired heart rate points, collected from 35 people. The temperature comparison covered 23 complete profiles with a mean absolute difference of 0.35 °C against a Braun thermometer used in the other ear. Wireless data loss during intense exercise reduced the number of complete profiles. Two ear devices agreeing tells us how they compare at that measurement site. The authors identify the absence of a direct core-temperature reference as a limitation.

Source 1 ↗

Read error in mmol/L alongside the correlation

For lactate, the team compared model predictions with blood measurements. The final model reported a correlation of 0.838. That shows how closely predicted and measured values tended to move together across the observations. The typical absolute size of the errors averaged 1.528 mmol/L. The reported limits of agreement reached from −4.52 to +4.55 mmol/L, a span of 9.07 mmol/L. Errors also tended to increase at higher lactate levels, with underprediction above the paper’s 4 mmol/L reference. A model can track the rise as a ride gets harder and still give a different value for a particular reading.

Source 1 ↗Source 2 ↗

What did adding heart rate contribute?

The smallest mean absolute error among the tested heart-rate-only models was 3.538 mmol/L. For temperature alone it was 1.642. The full five-feature model reached 1.528, 0.114 mmol/L lower than the best temperature-only result. The best models in those comparisons use different algorithms, so that difference cannot isolate the contribution of heart rate. The simplest model using both signals had an error of 1.670 mmol/L, slightly higher than the best temperature-only model.

Source 1 ↗

What would convince a reader that it travels?

The researchers left each participant’s data out in turn while fitting models using the other participants. This checks performance on people whose readings were held out of that fit inside the same study. A separate group tested under new conditions would show whether the errors travel outside this lab. A follow-up could report error by workload and the proportion of missing readings, alongside overall correlation and average error.

Source 1 ↗
TRACE THE EVIDENCE

Device agreement and prediction error answer different questions

Publisher full paper. Checked participant and reference device details, comparison tables, model evaluation, limits of agreement, limitations and disclosures.

01How close were the heart rate readings to the comparator?

What was observed
The mean absolute error against the chest strap was 0.89 beats/min.
Where the conclusion stops
It applies to paired readings in the indoor cycling experiment.

Source 1 · Figure 1 and Table 1

02Did high correlation imply narrow lactate errors?

What was observed
Correlation was 0.838 and the limits of agreement were −4.52 to +4.55 mmol/L.
Where the conclusion stops
Errors apply to this study cohort and increased at higher measured lactate.

Source 1 · Figure 3 and Table 3

Numbers you can inspect

MeasureValue & unitOrigin & method
Exercise volunteers36 peopleReported Count of healthy adults in the cycling study.
Source 1 · Methods, Participants
Participants with paired heart rate data35 peopleReported Paired device comparison.
Source 1 · Results, Heart rate validity
Complete temperature profiles23 peopleReported Complete profiles used in the temperature comparison.
Source 1 · Results, Temperature validity
Heart rate mean absolute error0.89 beats/minReported Compared with Polar H10 chest strap.
Source 1 · Figure 1
Ear temperature mean absolute error0.35 °CReported Compared with Braun ThermoScan 7 ear thermometer.
Source 1 · Figure 2
Best heart-rate-only model error3.538 mmol/L MAEReported Best mean absolute error for the heart-rate-only feature set.
Source 1 · Lactate prediction, ablation analysis
Best temperature-only model error1.642 mmol/L MAEReported Best mean absolute error for the temperature-only feature set.
Source 1 · Lactate prediction, ablation analysis
Best two-feature model error1.67 mmol/L MAEReported Linear regression using only the two basic features.
Source 1 · Lactate prediction, ablation analysis
Full model error1.528 mmol/L MAEReported Gradient boosting with five features.
Source 1 · Lactate prediction, ablation analysis
Difference in full vs temperature-only mean absolute error0.114 mmol/LCalculated Subtract 1.528 from 1.642. This compares separately selected models.
Source 1 · Lactate prediction, ablation analysis
Full model correlation0.838 Pearson rReported Association of predictions and measurements.
Source 1 · Lactate prediction, ablation analysis
Span between agreement limits9.07 mmol/LCalculated Subtract the lower limit of −4.52 from the upper limit of +4.55.
Source 1 · Figure 3 and Table 3

Compare the actual experiments

These studies answer different questions. Read the unit and endpoint before comparing results.

StudyUnit & settingReadoutInterpretation boundary
Two-device agreement in cycling and methodological agreement analysis

Source 2 · Bland and Altman, publication record

Paired measurementsMean absolute error, bias and limits of agreementRead the limits relative to the size of an error that matters in the intended setting.
Within-cohort and external model checks

Source 1 · Methods, Leave-One-Subject-Out cross-validation

Held-out individuals and a separate cohortError on unseen participants in the same studyA separate group can also challenge the collection conditions and population.
Download evidence table (CSV)

The export includes claims, available numbers, methods and source locations. It contains our reading notes and published summaries; it is not raw participant data or an independent reanalysis.

Evidence update · 22 Nov 2026
First publication. Any calculations in this brief use reported figures. The reading notes identify possible follow-up questions. AI source check; no human editorial or clinical review.

CONNECT THE EVIDENCE

What the earbud measured and what the model estimated

MeasurementReported average absolute errorReference and coverage
Heart rate0.89 beats/min mean absolute errorPolar H10 chest strap; paired data in 35 adults.
Ear temperature0.35 °C mean absolute errorBraun ear thermometer; 23 complete profiles.
Blood lactate prediction1.528 mmol/L mean absolute errorPrediction against sampled blood lactate; limits of agreement −4.52 to +4.55 mmol/L.

The three rows describe different measurements. The size of the numbers cannot be compared across units.

READER QUESTIONS

Your questions, answered

Did the earbud measure blood lactate directly?

The researchers measured blood lactate separately. A model estimated lactate using the wearable signals.

Why did the number of people differ by metric?

The study reports 36 volunteers, 35 with paired heart rate data and 23 with complete temperature profiles. Some temperature readings were lost during the test.

Does 0.838 correlation mean 84% accuracy?

It is a correlation coefficient. Mean absolute error and limits of agreement tell you how closely individual values matched in mmol/L.

Was the test done on a new outside group?

The leave-one-subject-out procedure used held-out participants from the same cohort. A study in a separately recruited group would test how well the model transfers.

LIMITATIONS

Limits of this interpretation

  • A controlled cycling test in healthy adults covers a limited setting and population.
  • The ear temperature comparison used a second ear device. Complete profiles were available for 23 of 36 volunteers.
  • The lactate model was exploratory. Performance was evaluated within the study cohort.
  • The authors reported no external research funding and declared no competing interests.
SOURCE NOTES

Sources & transparency

  1. Camargo, Zellhuber, Weber and Schönfelder (2026) — Assessment of the MOMENTUM sport earbud for multi-parametric physiological tracking and exploratory lactate modeling during incremental exercise

    Publisher full paper. Checked participant and reference device details, comparison tables, model evaluation, limits of agreement, limitations and disclosures. · Accessed 22 Nov 2026

    DOI: 10.1038/s41598-026-80803-8
  2. Bland and Altman (1986) — Statistical methods for assessing agreement between two methods of clinical measurement

    Original methods article, indexed publication record. The earbud paper supplies the application and numerical results. · Accessed 22 Nov 2026

    DOI: 10.1016/S0140-6736(86)90837-8

Prepared and source-checked with AI for Press-news Team. The source notes identify the material available during preparation. The article received no human editorial or clinical review. The source list supports the reported results and the calculations shown.

Source check: AI source check — primary research and stated source limits

Clinical review: Not applicable to this educational guide

Suggest a correction