The Virtual Therapist Platform translates motion from two wearable sensors into feedback on a screen. At the University of Talca in Chile, researchers tested the wireless link and then asked adults to rate an interaction with the system. Reading these results together is useful if each number keeps its own unit.

THE SHORT READ
  • After one supervised session, median usability scores were 97.5 out of 100 for 18 younger adults and 95.0 for 25 older adults.
  • A separate 30-minute test reported 99.68% packet delivery and a mean confirmation time of 8.03 milliseconds.
  • The study assesses immediate usability and a laboratory link. Sustained home use and changes in movement or daily function require separate measurement.
THE STUDY AT A GLANCEMotion monitoring for telerehabilitation · Gatica-Rojas and Vidal-Silva
Paper date
22 November 2026
Adults completing the usability assessment
43
Usability session
37 minutes, supervised
Wireless trial
30 minutes, two nodes

Original publication: 22 Nov 2026 · The date above refers to this brief.

THE NUMBERS, IN CONTEXT

Median usability scores after one supervised session

SUS points

Younger adults97.5
Older adults95
0100
Each adult answered once. The groups had 18 and 25 participants, respectively.
THE EXPERIMENT, EXPLAINED

Three stages of evidence for a home tool

  1. Test the link

    Measure the proportion of packets delivered and confirm when they arrived.

  2. Test the interaction

    Ask participants about a supervised session and record difficulties.

  3. Test the setting and outcomes

    Evaluate repeated independent home use and record changes that matter to participants.

The first two stages describe the study. The third is a proposed follow-up.

What a score of 97.5 measures

The System Usability Scale combines responses to ten questions into a 0-to-100 score. A score of 97.5 describes the middle participant score in the younger group. It does not count the percentage of people who accepted the device. For the older group the median was 95.0, and the middle half of the scores ran from 90.0 to 97.5. The two medians were 2.5 points apart. The earlier empirical work on the scale used it across products to summarise reported usability.

Source 1 ↗Source 2 ↗

Who contributed and what the comparison can tell us

The team screened 49 people and included 43 who completed the session, or 87.8% of those screened. The study compared 18 younger adults and 25 older adults. The rank comparison yielded p = 0.422, which leaves uncertainty about differences between the groups in the underlying population. The authors also did not systematically record participants’ prior familiarity with wearable devices or games. The high scores describe people who used the system with supervision.

Source 1 ↗

Follow the timing measurement to its endpoint

During the separate wireless trial, 99.68% of packets were delivered. The difference from 100% was 0.32 percentage points. The 8.03-millisecond mean timed confirmation of delivery over the tested link. A participant experiences additional stages as a movement is measured, processed and displayed. Timing the link leaves that end-to-end delay open. It also provides no direct measure of how accurately the screen reflects a moving person’s posture.

Source 1 ↗

What home use would add to the evidence

A home study could record whether people can set up the equipment or resume after interruptions, how often they use it over several weeks and how much assistance they require. A separate clinical study could compare outcomes such as changes in movement or daily function. Signals arriving and people finding an interface easy to use are useful early measurements. Each later question needs its own outcome and follow-up.

Source 1 ↗
TRACE THE EVIDENCE

Read the number with the measurement that produced it

Publisher full article. Checked the 30-minute transmission test, participant flow, session length, usability scores and limits for home and clinical use.

01Did the questionnaire scores measure acceptability?

What was observed
Both groups gave high perceived usability ratings immediately after a supervised session.
Where the conclusion stops
The scores describe immediate ratings. Long-term use and clinical outcomes need other measures.

Source 1 · Section 4.4

02What delay was measured?

What was observed
The mean delivery-confirmation latency was 8.03 ms.
Where the conclusion stops
The timing belongs to the wireless link and does not establish total feedback delay.

Source 1 · Sections 4.1 and 5

Numbers you can inspect

MeasureValue & unitOrigin & method
People screened49 peopleReported Eligibility screening before laboratory assessment.
Source 1 · Section 3.4 and Figure 5
People assessed43 peopleReported Enrolled and completed the assessment.
Source 1 · Section 3.4 and Figure 5
Assessed share of those screened87.8 percentCalculated Divide 43 by 49 and multiply by 100.
Source 1 · Figure 5
Younger adults assessed18 peopleReported Younger usability group.
Source 1 · Section 4.4
Older adults assessed25 peopleReported Older usability group.
Source 1 · Section 4.4
Younger median97.5 SUS pointsReported IQR 95.0 to 100.0.
Source 1 · Section 4.4
Older median95 SUS pointsReported IQR 90.0 to 97.5.
Source 1 · Section 4.4
Difference between group medians2.5 SUS pointsCalculated Subtract 95.0 from 97.5.
Source 1 · Section 4.4
Wireless packets delivered99.68 percentReported Delivery ratio under the controlled trial.
Source 1 · Section 4.1
Gap to delivery of every packet0.32 percentage pointsCalculated Subtract 99.68 from 100.
Source 1 · Section 4.1
Mean link confirmation time8.03 millisecondsReported Acknowledgment on the tested link.
Source 1 · Section 4.1

Compare the actual experiments

These studies answer different questions. Read the unit and endpoint before comparing results.

StudyUnit & settingReadoutInterpretation boundary
Usability after a supervised lab session

Source 2 · Bangor et al., questionnaire evaluation

Questionnaires completed by individual participantsPerceived ease of use on the System Usability ScaleFollow-up use, assistance and recovery from errors need their own measurements.
Link performance and movement outcome

Source 1 · Sections 4.1 and 5

Data packets and participantsDelivery ratio and eventual functional measuresA technically reliable link is one stage of validating a system.
Download evidence table (CSV)

The export includes claims, available numbers, methods and source locations. It contains our reading notes and published summaries; it is not raw participant data or an independent reanalysis.

Evidence update · 22 Nov 2026
First publication. Any calculations in this brief use reported figures. The reading notes identify possible follow-up questions. AI source check; no human editorial or clinical review.

CONNECT THE EVIDENCE

Which test produced each number?

MeasurementReported resultSetting and scale
Usability after a supervised session97.5 younger adults and 95.0 older adultsMedian questionnaire scores on a 0-to-100 scale.
Wireless delivery99.68% of packets deliveredDelivery ratio under a separate 30-minute test.
Confirmation time8.03 ms meanTime to confirm delivery on the tested link.

Sections 4.1 and 4.4 of the prototype study.

READER QUESTIONS

Your questions, answered

Were 97.5% of younger participants satisfied?

The value is the median of the 0-to-100 System Usability Scale scores. It is not a percentage of satisfied participants.

Do the medians show the system works equally well at all ages?

They describe two small groups who completed a supervised session. Testing equivalence would require a defined margin and a study designed to estimate it.

Was the 8.03 ms how quickly the person saw feedback?

The tested interval was the time to confirm wireless delivery. Displaying feedback introduces further stages.

Did participants continue using it at home?

The tested sessions were supervised and measured immediate usability. Independent use at home is a question for follow-up.

LIMITATIONS

Limits of this interpretation

  • The study involved a single supervised session. Repeated independent home use was outside its scope.
  • The age-group sample sizes and statistical comparison do not establish equivalence.
  • The link acknowledgment test measures part of the journey from moving a sensor to seeing feedback.
SOURCE NOTES

Sources & transparency

  1. Gatica-Rojas and Vidal-Silva (2026) — Wireless Motion Monitoring Using a Dual-Node ESP-NOW Architecture for Telerehabilitation

    Publisher full article. Checked the 30-minute transmission test, participant flow, session length, usability scores and limits for home and clinical use. · Accessed 22 Nov 2026

    DOI: 10.3390/app162311569
  2. Bangor, Kortum and Miller (2008) — An empirical evaluation of the System Usability Scale

    Original empirical study of the questionnaire across products. Checked what the scale measures and how it is interpreted. · Accessed 22 Nov 2026

    DOI: 10.1080/10447310802205776

Prepared and source-checked with AI for Press-news Team. The source notes identify the material available during preparation. The article received no human editorial or clinical review. The source list supports the reported results and the calculations shown.

Source check: AI source check — primary research and stated source limits

Clinical review: Not applicable to this educational guide